AT&TDEFINITY®CommunicationsSystem Generic 1andSystem 75Pocket Reference
EQUIPMENT AND MAXIMUMCABLING DISTANCESEQUIPMENT24-G26-GWIREWIRE(FEET)(FEET)Attendant Console 24001500Powered from Switch350 350510D or 515 Terminals 3
EQUIPMENT AND MAXIMUMCABLING DISTANCES (Contd)EQUIPMENT24-G26-GWIREWIRE(FEET)(FEET)Voice Terminals (Contd):Analog Line—16 Ports (TN746)(On-PremisesOnl
PROTOCOLSMAX.PROTOCOLAPPLICATIONSDATAMAX.RATEDISTANCE(kbps)(FEET)DCPDigital Switch to Data64.05000Endpointsfor data3400for voiceRS-232CPDM to AP (V1,
PROTOCOLS (Contd)PROTOCOLSDCPI(V1, V2, V3)RS-366V.35Category ACoaxialISDN PRI(G1)MAX. APPLICATIONSDATAMAX.RATEDISTANCE(kbps)(FEET)MPDM to AP64.0 17Hos
TRUNK SPECIFICATIONSTRUNKCIRCUITSPECIFICATIONSTYPEPACKCentralTN747B Capacity: 8 CircuitsOfficeTransmission: 1-Way In, 1-Way Out, or2-Way 2-Wire 600 Oh
TRUNK SPECIFICATIONS (Contd)TRUNKTYPEDS1 TrunkISDN PRIDS1 Interface(G1)CIRCUITPACKTN722BTN767SPECIFICATIONSCapacity: 24 Trunks for Voice Grade Service
SYSTEM PARAMETERSIn the SYSTEM PARAMETERS table, the following should beconsidered:●The headings V1, V2, V3 refer to System 75.●The heading G1 refer
SYSTEM PARAMETERSITEMV1 V2 V3G1Abbreviated Dial Lists:5028028021600Personal Lists4008008001600Max Entries10 101010Per Extension Number1333Group Lists1
SYSTEM PARAMETERS (Contd)ITEMV1V2 V3G1Automatic Alternate Routing(AAR) and Automatic RouteSelection (ARS)(Contd):NPAs (X-0/1-X)200 200 200200NXXs800 8
SYSTEM PARAMETERS (Contd)ITEMV1V2V3G1CabinetsSystem 75 and G1 MCC SystemBasic/PPN111 1EPN---1System 75 XE and G1 SCC SystemBasic/PPN Control-1 1 1Dupl
AT&TDEFINITY®CommunicationsSystem Generic 1andSystem 75Pocket ReferenceAddendum 1, DatedSeptember 1990 for555-200-202Issue 7, February 1990555-200
SYSTEM PARAMETERS (Contd)ITEMV1V2V3G1Centralized Attendant ServiceRelease Link Trunks (Branch)Release Link Trunks (Main)Branches Per Main-16--16200991
SYSTEM PARAMETERS (Contd)ITEMV1V2V3G1Intercom Groups (Automatic and Dial 32 32 3232Combined)Members per Group32 32 3232Members per System10241024 1024
SYSTEM PARAMETERS (Contd)ITEMV1V2 V3G1Port Circuit Pack Slots *PPN-Without Duplication Option858585 88(68) (68) (63)PPN-With Duplication Option---76(5
SYSTEM PARAMETERS (Contd)ITEMV1V2V3G1Remote Access Barrier Codes 1010 1010Reports Scheduled by Report Scheduler (G1)---50System Printers---1Restrictio
SYSTEM PARAMETERS (Contd)ITEMVoice Terminals:Combination of Digital, Hybridand Analog Terminals(Also includes 515 or 510Dterminals, external alerts, a
INTERFACE CIRCUIT PACKSV3, XEV2, XEV3, AND G1Processor Interface TN765●●●Provides 4 data links to the TDM bus and a link to the processorProvides AUDI
CONTROL CIRCUIT PACKSSYSTEM 75 V1, V2, AND V3 AND SYSTEM 75 XEV2AND XEV3Maintenance TN731 or TN731B (V1, V2, V3)●●●●Access to System Access Terminal (
CONTROL CIRCUIT PACKS (Contd)DEFINITY COMMUNICATIONS SYSTEM, G1Network Control TN777●●●●●●Continuously Monitors Port Circuit PacksTransfers Data to Pr
CONTROL CIRCUIT PACKS (Contd)DEFINITY COMMUNICATIONS SYSTEM, G1Duplication Interface TN772●Controls and provides the memory shadowing function with th
EXPANSION CONTROL CIRCUIT PACKSDEFINITY COMMUNICATIONS SYSTEM, G1Maintenance TN775●Controls and monitors the environmental and power systems in theEPN
TO ORDER COPIES OF THIS MANUALCall:AT&T Customer Information Center on1-800-432-6600.In Canada Call 1-800-255-1242Write:AT&T Customer Informat
PORT CIRCUIT PACKSAnalog Line(8-port)Analog Line(16-port)Analog Line(8-port)Analog Line(16-port)AnnouncementAuxiliary TrunkCO TrunkData Line (EIA)DID
POWER UNITSV1, V2, V3, XEV2, and XEV3631AR, 631WA1, or 631DA1 Power Unit (V1, V2, and V3)●Provides +5 volt dc 60-amp power on the backplane on the con
POWER UNITS (Contd)G1631DA1 Power Unit (G1)●Provides +5 volt dc 60-amp power on the backplane on the controlcarrier and the port carriers631DB1 Power
DATA MANAGEMENT FEATURESData Call SetupData Hot Line (all except V1)Data-Only Off-Premises ExtensionsData PrivacyData RestrictionDigital Multiplexed I
VOICE MANAGEMENT FEATURESAbbreviated DialingAP Demand Print (V1, V2, V3)Attendant Auto-Manual SplittingAttendant Call WaitingAttendant Control of Trun
VOICE MANAGEMENT FEATURES (Contd)Direct Outward Dialing (DOD)Direct Department Calling (DDC) andUniform Call Distribution (UCD)Direct Inward Dialing (
VOICE MANAGEMENT FEATURES (Contd)Recall SignalingRecorded AnnouncementRecorded Telephone Dictation AccessRemote AccessRestriction—ControlledRestrictio
NETWORK SERVICES FEATURESAAR/ARS Partitioning (V3, XEV3, and G1)Automatic Alternate Routing (AAR) (all except V1)Automatic Circuit Assurance (all ex
HOSPITALITY SERVICES FEATURES(V3, XEV3, and G1)Automatic WakeupDo Not DisturbHospitality Parameter ReductionNames Registration (G1)Property Management
REFERENCE DOCUMENTSVersionDocumentDocumentIss.NumberTitleNo.V1V2* V3*G1*350-060AT&T Telecommunication1 ✓ ✓ ✓✓Electrical Protection555-015-104DEFIN
Table of ContentsIntroduction1Design Benefits2FCC Information3Duplication Option3Environmental Requirements4Equipment and Maximum CablingDistances6810
REFERENCE DOCUMENTS (Contd)VersionDocument DocumentIss.NumberTitleNo.V1V2* V3*G1*555-200-600 DEFINITY5 ✓ ✓ ✓ ✓Communications SystemGeneric 1 and Syste
REFERENCE DOCUMENTS (Contd)VersionDocumentDocumentIss.Number TitleNo. V1 V2V3G1555-204-104DEFINITY2✓Communications SystemGeneric 1Installation and Tes
NOTES:Page 38
555-200-202Issue 7, February 1990 Graphics ® 1988 AT&T
INTRODUCTIONThis document is intended to be used as a quick reference for thefollowing systems:●DEFINITY Communications System Generic 1 (multi-carrie
DESIGN BENEFITSSystem Management Permits User Friendly Design,Implementation, and Administration by the CustomerA Two Port Network—The Processor Port
FEDERAL COMMUNICATIONS COMMISSION(FCC) INFORMATIONThe system FCC registration number is AS593M-13283-MF-E. The ringerequivalent is 0.5 ampere.DUPLICA
ENVIRONMENTAL REQUIREMENTS(System 75 and G1 multi-carrier cabinet)CABINETFully Loaded 5-Carrier (Medium) 800 Lbs 70"x32"x24"Fully Loade
ENVIRONMENTAL REQUIREMENTS(XEV2, XEV3, and G1 single-carrier cabinet)CABINETSingle Cabinet System130 Lbs20"x27"x22"Fully Loaded 4-Cabin