C-20 TRUNKING TERMS AND CAPABILITIES
_ ___________________________________________________________________________________________________________________________
_ ___________________________________________________________________________________________________________________________
_ ___________________________________________________________________________________________________________________________
_ ______________________________________________________________________________________
SWITCH A
FOR EACH "SWITCH A" TRUNKING OPTION (LISTED BELOW) — REFER TO THE
CORRESPONDING RECOMMENDED "SWITCH B" TRUNK OPTIONS (RIGHT FACING PAGE).
_ ______________________________________________________________________________________
GROUP/CALL TYPE DIREC- SUPERVISION SIGNALING
_ ____________________
TION
________________________________________________________
GENERIC 2, GS LS RB E&M ISDN INCOMING OUTGOING TIMEOUT
SYSTEM 85, OR
DIMENSION PBX "ALERTING" "ADDRESSING" (NOTE 3)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
18/CO OUT D-2 (NOTE 9)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
19/CO 2W D-1
________________________________________________________
Attendant 19
________________________________________________________
Completing/IN 28 AUTO IMMED-START
________________________________________________________
DOD 29 AUTO WINK-START (NOTE 10)
________________________________________________________
20 DMI-MOS DMI-MOS (NOTE 5)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
20/CO 2W D-2 (NOTE 9)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
21/FX IN D-1
________________________________________________________
Attendant 19
________________________________________________________
Completing 28 AUTO
________________________________________________________
29 AUTO (NOTE 4)
________________________________________________________
20 DMI-MOS (NOTE 5)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
22/FX OUT D-1
________________________________________________________
DOD 19
________________________________________________________
28 IMMED-START
________________________________________________________
29 WINK-START (NOTE 11)
________________________________________________________
20 DMI-MOS (NOTE 5)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
23/FX-DOD OUT D-2 (NOTE 9)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
24/FX 2W D-1
________________________________________________________
Attendant 19
________________________________________________________
Completing 28 AUTO IMMED-START
________________________________________________________
IN/DID 29 AUTO WINK-START (NOTE 4)
________________________________________________________
20 DMI-MOS DMI-MOS (NOTE 5)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
25/FX 2W D-2 (NOTE 9)
_ ______________________________________________________________________________________
Notes:
9. To be used with CO applications that provide a "party test" signal toward the PBX.
10. This trunk type and optional signaling arrangement may be used to build a "Special Access" trunk group. Although other trunk
group types may be more appropriate, this trunk group signaling arrangement may function to provide trunking facilities for
MEGACOM Service.