TABLE G. System Parameters
Item
G1
G3i
G3r
Abbreviated Dialing (AD)
AD Lists Per System
1,600
1,600 [2,400] 5,000
AD List Entry Size
24 24 24
AD Entries Per System
8,000
10,000 [12,000] 25,000
Auto Dialing Button (1)
Entries per System 2
2
2
Enhanced List (System List)
1
1
1
Max. entries
1,000
1,000
1,000
Group Lists
100
100
1,000
Max. entries 90 90 90
Group Iists/extension 3
3
3
System List
1
1
1
Max. entries 90
90
90
Personal Lists
1,600
2,000 [2,400]
5,000
Max. entries
10 10 10
Personal Iists/extension
3 3
3
Applications Adjuncts
ASAI Adjuncts
NA
8
8
Asynchronous Links (EIA-232)
5 5
10
SMDR Output Devices
2
2
2
Journal/System Printer
2/1 2/1
2/1
Property Management Systems
1
1 1
BX.25 Physical Links
8 8
16
Application Processors (i.e., 3B2-MCS)
1 1
7
AUDIX Adjuncts
1
1
5
CMS Adjuncts
1
1
1
ICM Adjuncts
ISDN Gateway
1
1
1
BX.25 Processor Channels 64 64
128
Hop Channels 64 64
128
Attendant ServIce
Attendant Consoles (day/night)
6/1
6/1 [15/1]
27/1
Attendant Console 100s Groups/Attendant
20
20
20
Attendant Control Restriction Groups 64 64 96
Centralized Attendant Service
Release Link Trunks at Branch 99 99
99
Release Link Trk Grp at Branch
1
1
1
Release Link Trunks at Main 400 400
4,000
Release Link Trk Grp at Main (2) 99 99 666
(1) G1/G3 Facility Busy Indicators are equivalent.