SYSTEM PARAMETERS
The following table shows the button module requirements of different station configurations.
TABLE D. Station Allocation Characteristics
Required Records Required Records and
Station Type
(G1,G3) Button Units*
Analog set 500 S S+62
Analog set 2500 S S+62
Analog set 7101A S S+62
Analog set 8102 S S+62
Analog set 8110 S S+62
10MET set - 10 buttons S S+52
20MET set - 20 buttons S + [B] S+152
30MET set - 30 buttons S + [B] S+252
Hybrid set - 7303S S S+102
Hybrid set - 7305S S + [B] S+342
Hybrid set - 7309S S S+102
Digital set - 7401D S S+92
Digital set - 7401 Plus S S+92
Digital set - 7403D S S+102
Digital set - 7404D S + M S+62
Digital set - 7404D w/display S + B + M S+192
Digital set - 7405D S + [B] S+342
Digital set - 7405D w/display S + B + [B] S+472
Digital set - 7406D S + [B] S+282
Digital set - 7406D w/display S + B + [B] S+342
Digital set - 7406 Plus S + [B] S+282
Digital set - 7407D (w/display) S + B + [B] S+472
Digital set - 7407 Plus S + B + [B] S+472
Digital set - 7410D S S+102
Digital set - 7434D S + [B] S+342
Digital set - 7434D w/call coverage module S + B + [B] S+542
Digital set - 7434D w/display S + 2B + [B] S+472
602A1 S + B + [B] S+342
PC S + B + [B] S+472
510BCT S + B + [B] + M S+322
515BCT S + B + M S+232
*
— Assumes 3 call appearances per station in button 1-3 with all other available buttons assigned.
— For call appearances other than 3, adjust total units by the following:
adjustment=(Nca-3)*[(10*Ndisp)+(6*Nbri)]
where: Nca=number of call appearance (assumes first Nca button is CA)
Ndisp=total number of display stations in system
Nbri=total number of BRI station in system
41
Kommentare zu diesen Handbüchern