AT&T Call Management System Betriebsanweisung Seite 106

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 276
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 105
[F3]
HoldTime Minimum
(Minimum Line Holding Time)
The line holding time refers to the length of time a line has been in use for a
single call. If you turn on this exception, CMS notifies you when the length
of time a line has been in use is less than the threshold you set. If the
holding time of a line is consistently short, it may signal a line problem.
Prompt:
MINIMUM HOLD-TIME (seconds): ON/OFF?___
Line Group A:___ B:___ C:___ D:___
Action:
1 Type on or off, or leave this field blank if you want to
keep the current value.
2
If you want to enter threshold values, enter a number of
seconds (1 through 99) for each line group. To keep the
current value, leave the field blank. To turn off this
exception for a particular line group, type a hyphen (-).
3
Press
[F8]
(labeled “Enter Data”) after the last field.
Message:
• • • Group X - Line XXXXX - Hold Time < = XX seconds
[F8]
Select Exceptns
(Select Exceptions)
Press this function key to return to the Select Exceptions screen.
[F10]
Help
Press this function key to display a Help screen or the Group Exceptions
screen.
4-62
Selecting Exceptions
Seitenansicht 105
1 2 ... 101 102 103 104 105 106 107 108 109 110 111 ... 275 276

Kommentare zu diesen Handbüchern

Keine Kommentare